Please Note:

The Open Access Repository will be moving to a new authentication system on the 1st of November.

From this date onwards, account holders will be required to login using their University of Tasmania credentials.
If your current repository username differs from your University username, please email E.Prints@utas.edu.au so we can update these details on your behalf.

Due to the change, there will be a short outage of the repository from 9am on the morning of the 1st of November

Open Access Repository

Analysis of single pole auto reclosure in extra high voltage systems

Downloads

Downloads per month over past year

Turnip, Sahala (1995) Analysis of single pole auto reclosure in extra high voltage systems. Coursework Master thesis, University of Tasmania.

[img] PDF (Whole thesis)
whole_TurnipSah...pdf | Request a copy
Full text restricted
Available under University of Tasmania Standard License.

Abstract

The successful single pole auto reclosure (SPAR) operation in the EHV system increases system stability, improves system reliability, reduces reclosing overvoltages and torsional impacts on generator shafts. The success rate of a SPAR operation is dependent on the time required to extinguish the secondary arc and to rebuild the dielectric strength of the de-ionized arc path. The extinction time of the secondary arc depends on the magnitude of the secondary arc current and the recovery voltage. Without a compensation scheme, a SPAR operation will be unsuccessful in a long EHV transmission line. Based on a three phase reduced system model, the performance of the main parameters of SPAR operations, the secondary arc current and the recovery voltage were analyzed. Detailed sensitivity analysis of SPAR operation in a long single circuit 500 kV transmission line was investigated for different line transposition scheme, line length, prefault line load and fault location using EMTDC software. A review of SPAR compensation methods is also included. Obtained results indicate a strong correlations between conductor configuration, line transposition schemes, line length, prefault line loading, fault location and compensation scheme, and the secondary arc current and the recovery voltage of SPAR operations.

Item Type: Thesis (Coursework Master)
Keywords: Electric lines, High voltages
Copyright Holders: The Author
Copyright Information:

Copyright 1995 the Author – The University is continuing to endeavour to trace the copyright owner(s) and in the meantime this item has been reproduced here in good faith. We would be pleased to hear from the copyright owner(s).

Additional Information:

Available for library use only and copying in accordance with the Copyright Act 1968, as amended. Thesis (MTech)--University of Tasmania, 1995. Includes bibliographical references

Date Deposited: 04 Feb 2015 23:31
Last Modified: 11 Mar 2016 05:55
Item Statistics: View statistics for this item

Actions (login required)

Item Control Page Item Control Page
TOP