Library Open Repository

Measurement of trace elements in marine environmental samples using solution ICP-MS. Current and future applications

Downloads

Downloads per month over past year

Maher, W and Krikowa, F and Kirby, J and Townsend, AT and Snitch, P (2003) Measurement of trace elements in marine environmental samples using solution ICP-MS. Current and future applications. Australian Journal of Chemistry, 56 (3). pp. 103-116. ISSN 0004-9425

[img] PDF
03_Maher_AustJChem.pdf | Request a copy
Full text restricted
Available under University of Tasmania Standard License.

Abstract

The strengths and weaknesses of using inductively coupled plasma mass spectrometer (ICPMS) measurements of samples in solution for marine environmental analyses using real world examples is discussed. ICPMS can detect nanogram per litre concentrations of trace elements but suffers from polyatomic interferences generated from the sample matrix. Most of the routine trace elements measured in marine biological tissue and sediment digests, with the notable exceptions of iron, chromium, vanadium, and selenium, are not subject to severe interferences. Low recoveries of trace elements from sediments are due to the inability of extraction acids to remove trace elements such as chromium and nickel from sediment matrices. The use of ICPMS offers the advantage that elements such as phosphorus, which previously required elaborate digestion procedures and a colorimetric determination, can be rapidly determined using nitric acid digestion alone. The use of flow injection coupled with ICPMS allows on-line preconcentration of trace metals and metalloids using chelation by ion-exchange resins or hydride generation and trapping as well as separation from matrix elements. Thus, the routine determination of trace elements and inorganic and methylated arsenic, antimony, mercury, and germanium species in open-ocean waters is possible. The coupling of HPLC and GC to ICPMS allows the measurement of metal and metalloid species in biological and sediment extracts. However, extraction of unaltered species from matrices presents a challenge. Many of the species found in the environmental samples are not known and analytical standards are not available. The concurrent use of HPLC-MS is needed to confirm these species.

Item Type: Article
Journal or Publication Title: Australian Journal of Chemistry
Page Range: pp. 103-116
ISSN: 0004-9425
Identification Number - DOI: 10.1071/CH02203
Additional Information: Definitive version available at: http://www.publish.csiro.au/nid/51.htm
Date Deposited: 10 Jan 2007
Last Modified: 18 Nov 2014 03:12
URI: http://eprints.utas.edu.au/id/eprint/566
Item Statistics: View statistics for this item

Repository Staff Only (login required)

Item Control Page Item Control Page