Library Open Repository

Separation of uranium(VI) and lanthanides by capillary electrophoresis using on-capillary complexation with arsenazo III

Downloads

Downloads per month over past year

Macka, M and Nesterenko, PN and Andersson, P and Haddad, PR (1998) Separation of uranium(VI) and lanthanides by capillary electrophoresis using on-capillary complexation with arsenazo III. Journal of Chromatography A, 803 (1-2). pp. 279-290. ISSN 0021-9673

[img] PDF
176.pdf | Request a copy
Full text restricted
Available under University of Tasmania Standard License.

Abstract

The viability of the separation of lanthanides and uranium(VI) in the form of strongly absorbing complexes with arsenazo III (AIII) was studied with the aim to increase the sensitivity of absorbance detection in determination of these metals by capillary electrophoresis (CE). Special attention was paid to the complexation equilibria in the background electrolyte (BGE). On-capillary complexation provided better peak shapes for lanthanides compared to pre-column complexation. While the BGE composition had very little effect on the peak shape of the kinetically inert uranium(VI) complex, it played a crucial role in the peak shapes of the kinetically labile lanthanide complexes. Addition of a second ligand competing with the metallochromic ligand AIII for the metal ions was found to be critical to achieve good peak shape. The nature and concentration of the competing complexing ligand added to the BGE, the pH, and the concentration of AIII were found to exert a strong influence on the separation selectivity, peak shapes and the detection sensitivity. Several carboxylic acids were compared as BGE competing ligands and citrate provided best selectivity and peak shapes. A citrate BGE at pH 4.7 and containing 0.1 mM AIII was used for the separation of uranium(VI) (350 000 theoretical plates) and LaIII (63 000 theoretical plates) while, to separate most lanthanides and uranium(VI), a similar BGE with a lower (0.03 mM) AIII concentration was used. Using hydrostatic sampling (100 mm for 10 s) detection limits of 0.35 μM (49 ppb) LaIII and 25 μM (60 ppb) UO2 were obtained. Using on-capillary complexation, sample stacking was retained for injection times of up to at least 100 s (ca. 30-mm sample plug) without loss of peak shapes for lanthanides or recovery for LaIII. When this process was used, the detection limit for LaIII was reduced to about 5 ppb. Optimal properties of metallochromic ligands for separation and detection of metals by CE are discussed.

Item Type: Article
Keywords: Uranium; Lanthanides; Arsenazo III
Journal or Publication Title: Journal of Chromatography A
Page Range: pp. 279-290
ISSN: 0021-9673
Identification Number - DOI: 10.1016/S0021-9673(97)01226-0
Additional Information: The definitive version is available online at http://www.sciencedirect.com/
Date Deposited: 22 Apr 2008 09:41
Last Modified: 18 Nov 2014 03:38
URI: http://eprints.utas.edu.au/id/eprint/6203
Item Statistics: View statistics for this item

Repository Staff Only (login required)

Item Control Page Item Control Page