			 http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/did/didmodel.xsd"><didl:Item><didl:Descriptior><didl:Statement mimeType="application/xml; charset=utf-8"><dii:Identifier xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="urn:mpeg:mpeg21:2002:01-DII-NS
		 	http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dii/dii.xsd" xmlns:dii="urn:mpeg:mpeg21:2002:01-DII-NS">http://eprints.utas.edu.au/3759/</dii:Identifier></didl:Statement></didl:Descriptior><didl:Descriptior><didl:Statement mimeType="application/xml; charset=utf-8"><oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/">
        <dc:title>New Fully Portable Instrument for the Versatile Determination of Cations and Anions by Capillary Electrophoresis with Contactless Conductivity Detection</dc:title>
        <dc:creator>Kuban, P</dc:creator>
        <dc:creator>Nguyen, HTA</dc:creator>
        <dc:creator>Macka, M</dc:creator>
        <dc:creator>Haddad, PR</dc:creator>
        <dc:creator>Hauser, PC</dc:creator>
        <dc:subject>240401 Optics and Opto-electronic Physics</dc:subject>
        <dc:description>A new portable capillary electrophoresis instrument with capacitively coupled contactless conductivity detection was&#13;
developed and optimized for the sensitive field measurements of ionic compounds in environmental samples. It is&#13;
powered by batteries and the high voltage modules are capable of delivering up to 15 kV at either polarity for more&#13;
than one working day. Inorganic cations and anions, including ions of heavy metals and arsenate, could be determined&#13;
with detection limits in the range from about 0.2 to 1 mM. The instrument was field tested in a remote region of&#13;
Tasmania and nitrite and ammonium could be determined on-site at concentrations as low as 10 ppb in presence of&#13;
other common inorganic ions at concentrations which were 2 to 3 orders of magnitude higher.</dc:description>
        <dc:publisher>Wiley-VCH</dc:publisher>
        <dc:date>2007</dc:date>
        <dc:type>Article</dc:type>
        <dc:type>PeerReviewed</dc:type>
        <dc:format>application/pdf</dc:format>
        <dc:identifier>http://eprints.utas.edu.au/3759/1/3759.pdf</dc:identifier>
        <dc:relation>http://dx.doi.org/10.1002/elan.200703908</dc:relation>
        <dc:identifier>Kuban, P and Nguyen, HTA and Macka, M and Haddad, PR and Hauser, PC (2007) New Fully Portable Instrument for the Versatile Determination of Cations and Anions by Capillary Electrophoresis with Contactless Conductivity Detection. Electroanalysis, 19 (19-20). pp. 2059-2065. ISSN 1040-0397</dc:identifier>
        <dc:relation>http://eprints.utas.edu.au/3759/</dc:relation></oai_dc:dc></didl:Statement></didl:Descriptior><didl:Component><didl:Descriptior><didl:Statement mimeType="application/xml; charset=utf-8"><dii:Identifier xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="urn:mpeg:mpeg21:2002:01-DII-NS
		 	    http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dii/dii.xsd" xmlns:dii="urn:mpeg:mpeg21:2002:01-DII-NS">http://eprints.utas.edu.au/3759/1/</dii:Identifier></didl:Statement></didl:Descriptior><didl:Resource ref="http://eprints.utas.edu.au/3759/1/3759.pdf"></didl:Resource></didl:Component></didl:Item></didl:DIDL>