<mets:mets LABEL="Eprints Item" xsi:schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-0.xsd" xmlns:xlink="http://www.w3.org/1999/xlink" OBJID="oai:utas.edu.au:4221" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:mods="http://www.loc.gov/mods/v3" xmlns:mets="http://www.loc.gov/METS/"><mets:metsHdr CREATEDATA="2009-01-08T03:42:24Z"><mets:agent TYPE="ORGANIZATION" ROLE="CUSTODIAN"><mets:name>UTas ePrints</mets:name></mets:agent></mets:metsHdr><mets:dmdSec ID="DMD_oai:utas.edu.au:4221_mods"><mets:mdWrap MDTYPE="mods"><mets:xmlData><mods:titleInfo><mods:title>Calculating the movement of MRI coils, and minimizing their noise</mods:title></mods:titleInfo><mods:name type="personal"><mods:namePart type="given">LK</mods:namePart><mods:namePart type="family">Forbes</mods:namePart><mods:role><mods:roleTerm type="text">author</mods:roleTerm></mods:role></mods:name><mods:name type="personal"><mods:namePart type="given">MA</mods:namePart><mods:namePart type="family">Brideson</mods:namePart><mods:role><mods:roleTerm type="text">author</mods:roleTerm></mods:role></mods:name><mods:name type="personal"><mods:namePart type="given">S</mods:namePart><mods:namePart type="family">Crozier</mods:namePart><mods:role><mods:roleTerm type="text">author</mods:roleTerm></mods:role></mods:name><mods:name type="personal"><mods:namePart type="given">PT</mods:namePart><mods:namePart type="family">While</mods:namePart><mods:role><mods:roleTerm type="text">author</mods:roleTerm></mods:role></mods:name><mods:abstract>The design of gradient coils within Magnetic Resonance Imaging equipment is considered. These coils produce linear magnetic fields in each of the three orthogonal directions in physical space. In addition, they are turned on and off repeatedly to enhance the clarity of the image, but this produces a great deal of noise within the coil, as its shape distorts under the influence of Lorentz forces. We present a method for calculating the movement of the coil in the background magnetic field, and estimating the consequent noise levels. This involves solving for the current density in the coil coupled with equations for its elastic deformation, along with acoustic equations for the pressure in the surrounding air. Winding patterns are designed to minimize the noise produced by the Magnetic Resonance Imaging coil.&#13;
</mods:abstract><mods:classification authority="lcc">249902 Medical Physics</mods:classification><mods:originInfo><mods:dateIssued encoding="iso8061">2007-09-15</mods:dateIssued></mods:originInfo><mods:originInfo><mods:publisher>Australian Mathematics Publ Assoc Inc</mods:publisher></mods:originInfo><mods:genre>Article</mods:genre></mets:xmlData></mets:mdWrap></mets:dmdSec><mets:amdSec ID="TMD_oai:utas.edu.au:4221"><mets:rightsMD ID="rights_oai:utas.edu.au:4221_mods"><mets:mdWrap MDTYPE="mods"><mets:xmlData><mods:useAndReproduction>
<p><strong>Permissions, Copyright and Authorship Statement</strong><br />
I grant the University of Tasmania permission to copy, store and
communicate this work  I declare that I either own the copyright in the
work or I am submitting this work with permission of the copyright owner
or under licence from the copyright owner. I declare that the metadata
regarding authorship are true and correct and that it complies with the
authorship requirements set down in the Joint NHMRC/AVCC Guidelines on
Research and Practice.</p>

<p>Clicking on the deposit button indicates your agreement to these 
terms.</p>
    </mods:useAndReproduction></mets:xmlData></mets:mdWrap></mets:rightsMD></mets:amdSec><mets:fileSec><mets:fileGrp USE="reference"><mets:file SIZE="563352" ID="oai:utas.edu.au:4221_7634_1" MIMETYPE="application/octet-stream" OWNERID="http://eprints.utas.edu.au/4221/1/4221.pdf"><mets:FLocat LOCTYPE="URL" xlink:href="http://eprints.utas.edu.au/4221/1/4221.pdf" xlink:type="simple"></mets:FLocat></mets:file></mets:fileGrp></mets:fileSec><mets:structMap><mets:div AMDID="TMD_oai:utas.edu.au:4221" DMDID="DMD_oai:utas.edu.au:4221_mods"><mets:fptr FILEID="oai:utas.edu.au:4221_7634_1"></mets:fptr></mets:div></mets:structMap></mets:mets>