<didl:DIDL xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:didl="urn:mpeg:mpeg21:2002:02-DIDL-NS" xsi:schemaLocation="urn:mpeg:mpeg21:2002:02-DIDL-NS 
			 http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/did/didmodel.xsd"><didl:Item><didl:Descriptior><didl:Statement mimeType="application/xml; charset=utf-8"><dii:Identifier xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="urn:mpeg:mpeg21:2002:01-DII-NS
		 	http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dii/dii.xsd" xmlns:dii="urn:mpeg:mpeg21:2002:01-DII-NS">http://eprints.utas.edu.au/560/</dii:Identifier></didl:Statement></didl:Descriptior><didl:Descriptior><didl:Statement mimeType="application/xml; charset=utf-8"><oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/">
        <dc:title>The determination of copper, zinc, cadmium and lead in urine by High Resolution Inductively Coupled Plasma Mass Spectrometry</dc:title>
        <dc:creator>Townsend, AT</dc:creator>
        <dc:creator>Miller, KA</dc:creator>
        <dc:creator>McLean, SR</dc:creator>
        <dc:creator>Aldous, S</dc:creator>
        <dc:subject>250402 Analytical Spectrometry</dc:subject>
        <dc:description>High resolution ICP-MS was used to determine Cu, Zn, Cd and Pb in urine. The effect of sample dilution,&#13;
preparation method and choice of internal standard were assessed. Sample dilution (1+9) with In as the internal&#13;
standard was found to offer an acceptable compromise between analytical accuracy and sample throughput. A&#13;
spectral resolution of 3000 was used to separate Cu and Zn isotopes from interferences commonly found in&#13;
biological matrices, while a resolution of 300, offering increased sensitivity and lower detection limits, was used for&#13;
Cd and Pb. The accuracy and precision of the analytical method were evaluated using two Bio-Rad Lyphochek&#13;
standard urines. The concentrations of Cu, Zn, Cd and Pb in Bio-Rad Level 1 reference urine were determined by&#13;
external calibration and were found to agree to within 0-17% of recommended values (Cu 48, Zn 710, Cd 6.5 and&#13;
Pb 14.3 ng g -1). Closer agreement of 0-7% was found for Bio-Rad Level 2 reference urine (Cu 63, Zn 1057, Cd 12.3&#13;
and Pb 69 ng g -1). Forty-two urine samples from seven workers occupationally exposed to Cd were analysed and&#13;
the results were compared with those obtained from 11 samples collected from four non-exposed volunteers. Similar&#13;
average concentrations of Cu and Zn were found in both groups when the results were normalised to creatinine&#13;
levels. Workers exposed to Cd were found to have an average urine Cd concentration elevated approximately&#13;
7-8-fold over that measured for the control group (about 2.2 compared with about 0.3 ng g -1, or 1.7 and 0.2 mg per&#13;
gram of creatinine when normalised). Urinary levels of Pb were slightly increased in the cadmium exposed workers&#13;
(about 6 compared with about 4 ng g -1).</dc:description>
        <dc:date>1998</dc:date>
        <dc:type>Article</dc:type>
        <dc:type>PeerReviewed</dc:type>
        <dc:format>application/pdf</dc:format>
        <dc:identifier>http://eprints.utas.edu.au/560/1/98_Urine_JAAS.pdf</dc:identifier>
        <dc:relation>http://dx.doi.org/10.1039/a805021j</dc:relation>
        <dc:identifier>Townsend, AT and Miller, KA and McLean, SR and Aldous, S (1998) The determination of copper, zinc, cadmium and lead in urine by High Resolution Inductively Coupled Plasma Mass Spectrometry. Journal of Analytical Atomic Spectrometry, 13 . pp. 1213-1219. ISSN 0267-9477</dc:identifier>
        <dc:relation>http://eprints.utas.edu.au/560/</dc:relation></oai_dc:dc></didl:Statement></didl:Descriptior><didl:Component><didl:Descriptior><didl:Statement mimeType="application/xml; charset=utf-8"><dii:Identifier xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="urn:mpeg:mpeg21:2002:01-DII-NS
		 	    http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dii/dii.xsd" xmlns:dii="urn:mpeg:mpeg21:2002:01-DII-NS">http://eprints.utas.edu.au/560/1/</dii:Identifier></didl:Statement></didl:Descriptior><didl:Resource ref="http://eprints.utas.edu.au/560/1/98_Urine_JAAS.pdf"></didl:Resource></didl:Component></didl:Item></didl:DIDL>