Open Access Repository

Considerations on contactless conductivity detection in capillary electrophoresis

Baltussen, E, Guijt, RM, van der Steen, G, Laugere, F, Baltussen, S and van Dedem, GWK 2002 , 'Considerations on contactless conductivity detection in capillary electrophoresis' , Electrophoresis, vol. 23, no. 17 , pp. 2888-2893 , doi: https://doi.org/10.1002/1522-2683(200209)23:17<2888::AID-ELPS2888>3.0.CO;2-4.

[img] PDF
RMG06.pdf | Request a copy
Full text restricted
Available under University of Tasmania Standard License.

Abstract

Nearly all analyses by capillary electrophoresis (CE) are performed using optical detection, utilizing either absorbance or (laser-induced) fluorescence. Though adequate for many analytical problems, in a large number of cases, e.g., involving non-UV-absorbing compounds, these optical detection methods fall short. Indirect optical detection can then still provide an acceptable means of detection, however, with a strongly reduced sensitivity. During the past few years, contactless conductivity detection (CCD) has been presented as a valuable extension to optical detection techniques. It has been demonstrated that with CCD detection limits comparable, or even superior, to (indirect) optical detection can be obtained. Additionally, construction of the CCD around the CE capillary is straightforward and robust operation is easily obtained. Unfortunately, in the literature a large variety of designs and operating conditions for CCD were described. In this contribution, several important parameters of CCD are identified and their influence on, e.g., detectability and peak shape is described. An optimized setup based on a well-defined detection cell with three detection electrodes is presented. Additionally, simple and commercially available read-out electronics are described. The performance of the CCD-CE system was demonstrated for the analysis of peptides. Detection limits at the μM level were obtained in combination with good peak shapes and an overall good performance and stability.

Item Type: Article
Authors/Creators:Baltussen, E and Guijt, RM and van der Steen, G and Laugere, F and Baltussen, S and van Dedem, GWK
Keywords: Capillary electrophoresis; Contactless conductivity detection; Peptides
Journal or Publication Title: Electrophoresis
ISSN: 0173-0835
DOI / ID Number: https://doi.org/10.1002/1522-2683(200209)23:17<2888::AID-ELPS2888>3.0.CO;2-4
Additional Information:

Copyright 2002 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

Item Statistics: View statistics for this item

Actions (login required)

Item Control Page Item Control Page
TOP