University of Tasmania
Browse

File(s) under permanent embargo

Anion-exchange capillary electrochromatography with indirect UV and direct contactless conductivity detection

journal contribution
posted on 2023-05-26, 15:44 authored by Emily HilderEmily Hilder, Zemann, A, Macka, M, Paul HaddadPaul Haddad
Conductivity detection is applied to ion-exchange capillary electrochromatography (IE-CEC) with a packed stationary phase, using a capacitively coupled contactless conductivity detector with detection occurring through the packed bed. Columns were packed with a polymeric latex-agglomerate anion-exchanger (Dionex AS9-SC). A systematic approach was used to determine suitable eluants for IE-CEC separations using simultaneous indirect UV and direct conductivity detection. Salicylate and p-toluenesulfonate were identified as potential eluant competing anions having sufficient eluotropic strength to induce changes in separation selectivity, but salicylate was found to be unsuitable with regard to baseline stability. It was also found for both indirect UV and direct conductivity detection that homogenous column packing was imperative, and monitoring of the baseline could be used to assess the homogeneity of the packed bed. Using a p-toluenesulfonate eluant, the separation of eight common anions was achieved in 2.5 min. Direct conductivity detection was found to be superior to indirect UV detection with regard to both baseline stability and detection sensitivity with detection limits of 4-25 g/L being obtained. However, the calibration for each anion was not linear over more than one order of magnitude. When using conductivity detection, the concentration of the eluant could be varied over a wider range (2.5-50 mM p-toluenesulfonate) than was the case with indirect UV detection (2.5-10 mM), thereby allowing greater changes in separation selectivity to be achieved. By varying the concentration of p-toluenesulfonate in the eluant, the separation selectivity could be manipulated from being predominantly ion-exchange in nature (2.5 mM) to predominantly electrophoretic in nature (50 mM).

History

Publication title

Electrophoresis

Volume

22

Article number

7

Number

7

Pagination

1273-1281

ISSN

0173-0835

Publication status

  • Published

Rights statement

The definitive published version is available online at: http://interscience.wiley.com

Repository Status

  • Restricted

Usage metrics

    University Of Tasmania

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC