Please Note:

The Open Access Repository has moved to a new authentication system as of the 1st of November.

Account holders will now be able to login using their University of Tasmania credentials.
If you have trouble logging in please email us on E.Prints@utas.edu.au so we can assist you.

Public users can still access the records in this repository as normal

Open Access Repository

Numerical methods for comparing fresh and weathered oils by their FTIR spectra

Downloads

Downloads per month over past year

Li, J and Hibbert, DB and Fuller, S (2007) Numerical methods for comparing fresh and weathered oils by their FTIR spectra. Analyst, 132 (8). pp. 792-800. ISSN 0003-2654

[img] PDF
0792_-_0800_Li...pdf | Request a copy
Full text restricted
Available under University of Tasmania Standard License.

Abstract

Four comparison statistics (similarity indices) for the identification of the source of a petroleum oil spill based on the ASTM standard test method D3414 were investigated. Namely, (1) first difference correlation coefficient squared and (2) correlation coefficient squared, (3) first difference Euclidean cosine squared and (4) Euclidean cosine squared. For numerical comparison, an FTIR spectrum is divided into three regions, described as: fingerprint (900–700 cm–1), generic (1350–900 cm–1) and supplementary (1770–1685 cm–1), which are the same as the three major regions recommended by the ASTM standard. For fresh oil samples, each similarity index was able to distinguish between replicate independent spectra of the same sample and between different samples. In general, the two first difference-based indices worked better than their parent indices. To provide samples to reveal relationships between weathered and fresh oils, a simple artificial weathering procedure was carried out. Euclidean cosine and correlation coefficients both worked well to maintain identification of a match in the fingerprint region and the two first difference indices were better in the generic region. Receiver operating characteristic curves (true positive rate versus false positive rate) for decisions on matching using the fingerprint region showed two samples could be matched when the difference in weathering time was up to 7 days. Beyond this time the true positive rate falls and samples cannot be reliably matched. However, artificial weathering of a fresh source sample can aid the matching of a weathered sample to its real source from a pool of very similar candidates.

Item Type: Article
Journal or Publication Title: Analyst
Page Range: pp. 792-800
ISSN: 0003-2654
Identification Number - DOI: 10.1039/b703785f
Date Deposited: 29 Jan 2009 02:23
Last Modified: 18 Nov 2014 03:55
Item Statistics: View statistics for this item

Actions (login required)

Item Control Page Item Control Page